show interfaces gigabitEthernet i-sid

Display all configured service instance identifiers (I-SID) on port.

Syntax

Command Parameters

{slot/port[/sub-port][-slot/port[/sub-port]][,...][slot/all][all]}

Identifies the slot and port in one of the following formats:

  • a single slot and port (slot/port)

  • a range of slots and ports (slot/port-slot/port)

  • a series of slots and ports (slot/port,slot/port,slot/port)

  • all ports on the same slot (slot/all)

  • all ports on the switch (all)

If the platform supports channelization and the port is channelized, you must also specify the sub-port in the format slot/port/sub-port.

Default

None

Command Mode

Privileged EXEC

Command Output

The show interfaces gigabitEthernet i-sid command displays the following information:

Output field

Description

PORTNUM

Specifies the port number.

IFINDEX

Specifies a value that uniquely identifies the port.

ISID ID

Specifies the service interface identifier (I-SID).

VLANID

Specifies the backbone VLAN.

C-VID

Specifies the customer VLAN ID.

ISID TYPE

Specifies the type of I-SID.

ORIGIN

Specifies the origin of the service associated with the I-SID interface.

ISID NAME

Specifies the name of the I-SID.

BPDU

Specifies the BPDU forward option for the untagged traffic port.

MAC SUNI

Specifies the Switched UNI MAC address.

Example

The following example shows the configured service instance identifiers (I-SID) on a port.

Switch:1#show interfaces gigabitEthernet i-sid
=======================================================================================
                           PORT Isid Info
=======================================================================================
                ISID                   ISID                        ISID              MAC
PORTNUM IFINDEX ID       VLANID C-VID  TYPE     ORIGIN             NAME        BPDU  SUNI
----------------------------------------------------------------------------------------
1/1     192     27       N/A    4000   ELAN     C  ---  -  ---  -  ISID-27           FALSE
1/1     192     270      N/A    4001   ELAN     C  ---  -  ---  -  ISID-270          FALSE
1/1     192     309      N/A    309    ELAN     C  ---  -  ---  -  ISID-309          FALSE
1/1     192     401      N/A    401    ELAN     C  ---  -  ---  -  ISID-401          FALSE
1/1     192     1001     N/A    1001   ELAN     C  ---  -  ---  -  ISID-1001         FALSE
1/1     192     1111     N/A    1111   ELAN     C  ---  -  ---  -  ISID-1111         FALSE
1/1     192     1121     N/A    1121   ELAN     C  ---  -  ---  -  ISID-1121         FALSE
1/1     192     1201     N/A    1201   ELAN     C  ---  -  ---  -  ISID-1201         FALSE
1/1     192     2001     N/A    2001   ELAN     C  ---  -  ---  -  ISID-2001         FALSE
1/2     193     38       N/A    4000   ELAN     C  ---  -  ---  -  ISID-38           FALSE
1/2     193     310      N/A    310    ELAN     C  ---  -  ---  -  ISID-310          FALSE
1/2     193     380      N/A    4001   ELAN     C  ---  -  ---  -  ISID-380          FALSE
1/2     193     402      N/A    402    ELAN     C  ---  -  ---  -  ISID-402          FALSE

13 out of 152 Total Num of i-sid endpoints displayed

ORIGIN Legend:
C: manually configured; D: discovered by FA or EPT
M: FA management; E: discovered by EAP; A: auto-sense
l: discover by local switch  r: discover by remote VIST switch